Extron electronic USP 507 manual SIS Programmer’s Guide, cont’d, Command, ASCII command, Response

Models: USP 507

1 96
Download 96 pages 45.48 Kb
Page 50
Image 50
Picture in Picture

SIS Programmer’s Guide, cont’d

Command

ASCII command

Response

Additional description

 

(host to processor\⤀

(processor to host\⤀

 

 

 

 

 

Picture in Picture

 

 

 

PIP on/off

 

 

 

PIP input select

E X!PIP}

PipX!]

Turn PIP on and display input

 

 

 

X!.

PIP off

E0PIP}

Pip0]

Turn PIP off.

View PIP status

EPIP}

X! ]

View PIP window selection.

NWhen PIP is enabled, all picture control commands apply to the image in the PIP window.

Swap PIP

Swap

%

Tke]

Swap content between main

 

 

 

and PIP window.

On-screen clock

 

 

 

Enable on-screen clock

E X5^TIME}

TimeX5^]

Display the time on the video

 

 

 

output.

View settings

ETIME}

X5^]

View setting.

On-screen clock horizontal position

Specific value

E K X1^HCTR}

HctrKX1^]

Increment up

EK +HCTR}

HctrKX1^]

Increment down

EK -HCTR}

HctrKX1^]

View settings

EK HCTR}

X1^]

Set horizontal position to X1^. Shift clock right.

Shift clock left.

Horizontal position is X1^.

On-screen clock vertical position

Specific value

E K X1^VCTR}

VctrKX1^]

Increment up

EK +VCTR}

VctrKX1^]

Increment down

EK -VCTR}

VctrKX1^]

View settings

EK VCTR}

X1^]

Set vertical centering to X1^. Shift clock down.

Shift clock up.

Vertical position value is X1^.

N X! = Input selection

1 – 7

X1^ = H and V position

zero location is 2048, and limits are ± the output resolution

X5^ = On-screen clock

0 = disabled (default), 1 = date and time, 2 = time only, 3 = date only.

4-14 USP 507 • SIS Programmer’s Guide