Alarms 9

Alarm Editor

Multi-QoS Alarms

For Multi-QoS alarms, alarms can be created from the Multi-QoS Views interface as well as by double-clicking on the host.

The Codecs field within the alarm editor allows you select a specific codec or to ignore the type of codec used. For example, to trigger the alarm only when a G.711 codec is used, set the Codecs field to G.711. To trigger the alarm without looking at the codec type, set the Codecs field to All Codecs.

Multi-QoS uses a simple threshold value to trigger the alarm. When the threshold value is crossed, the alarm is triggered and the alarm action is taken. Most alarms trigger when the current value exceeds a threshold, such as for call jitter. However, the R-factor alarms trigger when the current value goes below the threshold value. The lower the R-factor, the lower the call quality, so alarms trigger when the R- factor drops below a threshold.

The alarm conditions are checked for each call; if threshold values are reached, alarms will trigger only once per call.

9-5

Page 189
Image 189
Finisar Surveyor manual Multi-QoS Alarms