Finisar Surveyor manual NCP Read/Write Overlap

Models: Surveyor

1 454
Download 454 pages 42.92 Kb
Page 228
Image 228

Surveyor

User’s Guide

NCP Read/Write Overlap

Counter

NCP Read/Write Overlap is a counter of all times where a portion of a file overlaps the transmission of other parts of the file. A count of all NCP Read/Write Overlap events displays in the Overview counters of Expert View.

Expert Symptom

NCP Read/Write Overlap events are automatically logged as expert symptoms. The Symptom Summary field provides the two addresses between which the overlap occurred. For example:

Between [00000010.0207012303E3] and [302A9950.000000000001]

Diagnostic Details

__________________________________________________________________

Problem Description:

A part of a transmitted file overlaps with the other parts.

__________________________________________________________________

Probable Cause(s):

1. There may be a problem with the NCP client application.

__________________________________________________________________

Recommended Action(s):

1. Upgrade the NCP client application.

10-24

Page 228
Image 228