Finisar Surveyor manual Oversized Frame, Oversized frame has more than 1518 bytes

Models: Surveyor

1 454
Download 454 pages 42.92 Kb
Page 319
Image 319

Expert Features 10

MAC Layer

Oversized Frame

Counter

The Oversize Frame counter increments when a frame has a CRC error and is greater than 1518 bytes in length. A count of all Oversize Frames is included in the Bad Frames counter that displays in the Overview counters of Expert View. The Oversize Frame counter is used for Expert Alarms.

Expert Symptom

Oversized Frame events are automatically logged as expert symptoms. The Symptom Summary field contains the following information:

Oversized frame has more than 1518 bytes

Diagnostic Details

__________________________________________________________________

Problem Description:

A packet with more than 1518 bytes of data has been received.

__________________________________________________________________

Probable Cause(s):

1.A faulty hub/switch/router device.

2.An end station may have a faulty network interface card.

3.A protocol analyzer has been transmitting error packets.

__________________________________________________________________

Recommended Action(s):

1. Find out the source device and fix the problem.

10-115