Finisar Surveyor manual Expert Counters

Models: Surveyor

1 454
Download 454 pages 42.92 Kb
Page 373
Image 373

Counters 12

Expert Counters

Expert Counters

Expert counters count the number of Export events discovered by Surveyor’s expert logic. Some counters are used in the Expert Alarm editor and some display in the Overview Table of Expert View. See the Expert Systems chapter for more information on expert counters.

The following table contains an alphabetical list, with descriptions, of Surveyor’s expert counters.

.

Table 12-4. Alphabetical List and Descriptions of Expert Counters

Counter Type

Description

 

 

Bad Frames

The number of bad frames including CRC frames, jabber frames,

 

runt frames, oversize frames, and fragment frames.

 

 

Broadcast/Multicast Storms

The number of Broadcast/Multicast Storm events. The event

 

occurs when a change in the number of total Broadcast/Multicast

 

packets per second exceeds a threshold.

 

 

Duplicate Network Address

The number of duplicate network addresses over a period of time

 

per segment.

 

 

Excessive ARP

The number of Excessive ARP events. The event occurs when a

 

change in the number of ARP requests per second exceeds a

 

threshold.

 

 

Excessive BOOTP

The number of Excessive BOOTP events. The event occurs when

 

a change in the number of BOOTP/DHCP requests per second

 

exceeds a threshold over a period of time per segment.

 

 

Excessive Broadcasts

The number of broadcast messages over a period of time per seg-

 

ment.

 

 

Excessive Collisions

The absolute number of collisions over a period of time per seg-

 

ment.

 

 

Excessive Mailslot Broad-

The number of mailslot broadcast events over a period of time per

casts

segment.

 

 

Excessive Multicasts

The number of multicast messages over a period of time per seg-

 

ment.

 

 

HSRP Errors

The number of HSRP Coup and Resign messages over a period of

 

time per segment.

 

 

ICMP All Errors

The number of ICMP symptoms. This includes all destination

 

unreachable errors, redirect errors, source quench, time-out errors,

 

and parameter problems.

 

 

12-5

Page 373
Image 373
Finisar Surveyor manual Expert Counters