Configuring Surveyor 4

Module Settings (Properties)

Module Settings (Properties)

Module settings configure options for the capture, monitor, and transmit functions of devices. To configure modules, select Module Settings... from the Configuration menu. Tabs appear that apply to the currently active device type; a tab will only appear if this option can be set for the current device type. Hardware devices can have properties set according to Table 4-3 below:

Table 4-3. Hardware Device Properties

Hardware

Set

Packet

Stop-and-

Modes:

Modes:

Modes:

MAC

Device

Buffer

Slice

Save

Expert

Non-

M-QoS

Control

 

Size

 

Capture

Mode

WKP

Only

Frame

 

 

 

 

 

 

 

 

THGm

NO

YES

YES

YES

YES#

YES

YES

THGs

NO

YES

NO

YES

NO

YES

YES

 

 

 

 

 

 

 

 

THGsE

NO

YES

NO

YES

NO

YES

YES

 

 

 

 

 

 

 

 

THGp

NO

YES

YES

YES

NO

YES

YES

 

 

 

 

 

 

 

 

Portable

YES

YES

YES

YES

YES#

YES#

NO

Surveyor 10/

 

 

 

 

 

 

 

100 Ethernet

 

 

 

 

 

 

 

Analyzer Card

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NDIS

YES

YES

YES

YES

YES#

YES#

NO

#This option affects the display of tables for local devices only for 10/100 networks.

4-7

Page 67
Image 67
Finisar Surveyor manual Module Settings Properties, Hardware Device Properties