Finisar manual Configuring Surveyor

Models: Surveyor

1 454
Download 454 pages 42.92 Kb
Page 63
Image 63
Protocol Summary
Display Detail

 

 

Configuring Surveyor

4

 

 

Configuring the Interface

 

Table 4-1. Configurable Capture View Columns

 

 

 

 

 

 

 

Capture View Column

Description

 

 

 

 

 

 

 

 

Abs Time

The absolute time of arrival for each packet taken from the system

 

 

 

 

clock when the capture was performed.

 

 

 

 

format: hh:mm:ss.mmm.uuu.nnn where ss=seconds,

 

 

 

 

mmm=milliseconds, uuu=microseconds, nnn=nanoseconds

 

 

 

 

 

 

 

 

Delta Time

The time between each packet (interpacket gap).

 

 

 

 

format: s.mmm.uuu.nnn where s=seconds, mmm=milliseconds,

 

 

 

 

uuu=microseconds, nnn=nanoseconds

 

 

 

 

 

 

 

 

Elapsed Time

The time stamp of each packet measured from a relative starting

 

 

 

 

point. The starting point may be either the module arm time or the

 

 

 

 

arrival time of a specific packet. See below for information on setting

 

 

 

 

the elapsed time starting point.

 

 

 

 

 

 

 

 

Size

The frame size of the packet in bytes.

 

 

 

 

 

 

 

 

Status

The Status field indicates if the frame has errors. For good frames, the

 

 

 

 

Status field is blank.

 

 

 

 

 

 

 

 

Display Network Address

The destination and source IP address.

 

 

 

 

 

 

 

 

Cumulative Byte/

The Cumulative Byte Count is a sum of all bytes received to this point

 

 

 

Throughput

in time in a capture file. The Throughput is calculated by dividing the

 

 

 

 

cumulative bytes by the elapsed time. The elapsed time is the differ-

 

 

 

 

ence is always measured between the module arm time and the time

 

 

 

 

stamp of the current packet in the capture file.

 

 

 

 

 

 

 

Use the middle portion of the dialog box to set up the display of the Summary column. The Summary column will always display. However, this field can just give a very limited synopsis of protocol activity or provide complete details about the protocols used in the packet. Check the Display Detail Protocol Summary box to view detail about all the protocols used in the packet. Leaving the

box unselected gives a synopsis of all protocols in the packet. If you want to display protocol summary details, set the protocols you want to display from the pull-down menu. For example, if you want to display only the Transport layer and below, select Transport Layer. If you are not displaying protocol summary details, the protocol layer you select in the pull-down menu will not affect the display of the Summary.

Select the Display Expert Symptoms check box if you wish to include expert symptom information in the Summary field. Packets that trigger an expert symptom and have expert symptom information will display in reverse video in Capture View.

4-3