Alarms 9

Alarm Examples

Alarm Examples

The following are six examples for alarms and alarm groupings. Each provides a picture of the Current Module Alarms dialog box and a description of what will occur when for the alarms are triggered.

Alarm Example, Utilization

Figure 9-6. Alarm Example, Utilization

This simple example shows an alarm group consisting of one MAC Layer alarm for Utilization. This alarm samples network traffic at five-second intervals. When the absolute, rising value of 50 (percent utilization) is exceeded, Surveyor issues an audible alarm and displays a message in Surveyor’s message window.

9-15

Page 199
Image 199
Finisar Surveyor manual Alarm Examples, Alarm Example, Utilization