Finisar Surveyor manual Updating an Analyzer Device, Click the Reset Host/Image Upgrade button

Models: Surveyor

1 454
Download 454 pages 42.92 Kb
Page 79
Image 79

Configuring Surveyor 4

Settings for Analyzer Devices

2.Click on the icon for the remote analyzer device in the Resource Browser.

3.Choose Properties from the Host menu.

4.Click the Reset Host/Image Upgrade button.

5.Check the Warm Boot radio button under Reset Options. Leave all other fields blank or unmarked.

6.Click the OK button.

When you reset a remote analyzer device, you will lose the connection. Use the Connect option from the Remote menu to reconnect.

Updating an Analyzer Device

You can update the software or change address information for a Finisar analyzer device from Surveyor.

Before you can reset the device with a new image, you must place the new image on a server that runs TFTP protocol.

Download the new software from the support web site, http://www.finisar.com. Go to the software updates section of the Web site to find the new analyzer image. Place the software on the server that runs the TFTP protocol.

Before you can update the analyzer address information automatically, you must have a server that contains the new address information and runs the BOOTP proto- col.

Use the following procedure to update the analyzer image software.

1.Login to the remote analyzer device with “super-user” privileges.

2.Click on the icon for the analyzer device in the Resource Browser.

3.Choose Properties from the Host menu.

4.Set the new IP Address, IP Gateway Address, and Subnet Mask for the analyzer. If no address update is needed, or you are updating the address from a BOOTP server, skip this step.

5.Click the Reset Host/Image Upgrade button.

6.Check the Enable BOOTP box if you are updating addresses from a BOOTP server.

7.Check the Image Upgrade (TFTP) box if you are updating addresses from a TFTP server.

4-19

Page 79
Image 79
Finisar Surveyor manual Updating an Analyzer Device, Click the Reset Host/Image Upgrade button