Table 12-3 contains an alphabetical list, with descriptions, of Surveyor’s Token Ring error counters.

Table 12-3. Alphabetical List and Descriptions of Token Ring Error Counters

Token Ring Counter

Description

 

 

Abort Delimiter

Records events where a reporting Ring Station encounters recover-

 

able internal errors, forcing it to transmit an Abort Delimiter frame.

 

 

AC Error

Records events where the reporting Ring Station’s nearest active

 

upstream neighbor could not set the address recognized bits or frame

 

copied bits in the newly transmitted frame after copying the bits on the

 

last frame received.

 

 

Burst Error

Records events where the reporting Ring Station encounters signal

 

transition or signal error on the Token Ring physical medium

 

 

Frame Copy

Records when a reporting Ring Station copies a frame containing the

 

Ring Station’s own (duplicate) address.

 

 

Frequency

Records events where the reporting Ring Station attempts to receive a

 

frame containing an improper ring-clock frequency.

 

 

Internal Error

Records events where the reporting Ring Station encounters a recov-

 

erable internal error.

 

 

Line Error

Records events where the reporting Ring Station’s checksum process

 

detects an error in a received data frame or token that the Ring Station

 

transmitted.

 

 

Lost Frame

Records events where a reporting Ring Station generates a frame to a

 

specific address and does not receive the returned frame.

 

 

Token Error

Records events where the Token Ring Active Monitor does not detect

 

a ring token.

 

 