Fortinet Version 3.0 Recovering from a FortiGate failure, To add and enable an Snmp community

Models: Version 3.0

1 88
Download 88 pages 53.91 Kb
Page 43
Image 43

 

 

Configuration and operating procedures

Recovering from a FortiGate failure

To add and enable an SNMP community

1Log into the CLI.

2Add the first SNMP community and name it snmp1. Enter:

config system snmp community edit 1

set name snmp_1

end

The new SNMP community is enabled by default. SNMP v1 and v2 traps are also enable by default. You can disable traps and change ports. See “system snmp community” on page 71 for more information.

3Add the IP addresses of two SNMP managers that can receive traps. Enter

config system snmp community edit 1

config hosts edit 1

set ip 172.20.120.12

next edit 2

set ip 192.168.20.102

end

end

Recovering from a FortiGate failure

After the FortiBridge probe detects a FortiGate failure the FortiBridge unit stops sending probes. To restart probes you can restart the FortiBridge unit, connect to the FortiBridge CLI and enter the execute switch-modecommand, or press the mode button on the FortiBridge unit front panel.

Normally, an action on failure causes the FortiBridge unit to fail open. When the FortiBridge unit fails open, it begins operating in Bypass mode. In bypass mode the INT 1 and EXT 1 interfaces are directly connected and you cannot use Telnet or SSH to connect to the FortiBridge CLI. Use the following procedure to recover from bypass mode after a FortiGate failure and resume normal operation.

To resume normal operation from bypass mode

When the FortiBridge unit is operating in bypass mode, you need to do the following to resume normal operation:

1Review FortiBridge alerts and check the status of your FortiGate unit and network components to determine the source of the failure.

A network component or the FortiGate unit could have experienced a general hardware failure or a specific software failure.

FortiBridge Version 3.0 Administration Guide

43

09-30000-0163-20061109

Page 43
Image 43
Fortinet Version 3.0 manual Recovering from a FortiGate failure, To add and enable an Snmp community