Model LR16 [Mixer functions]

(4)Adjust the effected (wet) signal level sent to the stereo L/R buss using the control in the [EFFECT TO STEREO] section

Adjust the effected signal level while monitoring the stereo buss signal using headphones or monitor speakers.

<Memo>: To send the effected signal to the group or AUX busses, use the controls in the [EFFECT TO GROUP] or [EFFECT TO GROUP] section.

• About the effect types

HALL 1

Standard hall reverb; detailled and trans-

parent, with a moderate amount of early

 

reflections.

 

 

HALL

Stadium reverb characterized by long

early reflections.

 

 

 

STADIUM

Reverb simulating an auditorium with

suppressed reverberation.

 

 

 

ROOM

Room reverb simulating a moderate

 

Monitoring

You can monitor the signal using headphones via the [PHONES] jack or using monitor speak- ers via the [MONITOR L/R] jacks.

The signal to be monitored can be selected using the [MONITOR SELECT] switch. Each press of the switch changes the monitor sig- nals and the indicator for the current moni- tor signal (ST, 1-2, 3-4 or EFF RTN) is lit.

 

space with some sparkle.

 

 

PLATE 1

Modem-sounding plate reverb with wide

bandwidth.

 

 

 

PLATE 2

Plate reverb with a gentle character.

 

 

 

All-purpose hall reverb with no early re-

Level meters

Indicators

[MONITOR SELECT]

switch

VOCAL1

flections, and uniform decay at all fre-

 

quencies.

 

 

 

Plate-like reverb is added to a spacious

VOCAL 2 short delay. This blends well with any

 

genre of music.

 

 

VOCAL 3

All-purpose reverb (karaoke style) that

makes any vocal sound professional.

 

 

 

Mono DLY

Mono delay.

 

 

Pan DLY

Panning delay.

 

 

Short DLY

Short delay.

 

You can monitor the stereo L and R buss signal,

ST

which is output from the [STEREO OUT (L, R)]

 

jacks.

 

 

1-2

You can monitor the group 1 and 2 buss signals,

which are output from the [GROUP (1, 2)] jacks.

 

 

 

3-4

You can monitor the group 3 and 4 buss signals,

which are output from the [GROUP (3, 4)] jacks.

 

 

 

EFF

You can monitor the output signal (wet signal) of

RTN

the internal effects processor.

 

 

The output level of the [PHONES] jack is con- trolled by the [MONITOR] and [PHONES] con- trols, while the output level of the [MONITOR L/R] jacks is controlled by the [MONITOR] control. The output levels of the monitoring signals are shown on the level meters above the [MONITOR SELECT] switch.

<Note>: If any of the [SOLO] switches is set to ON, the solo signal is monitored, while the sig- nal selected by the [MONITOR SELECT] switch is interrupted.