Model LR16 [Recorder function / Other functions]

The display now shows the system menu screen.

(3)Use the [MENU] dial to highlight "Sys default memory" and press the [ENTER] key.

The confirmation screen as below is shown.

<Memo>: To cancel system initialization, press the [STOP] key.

(4)While holding down the [RECORD] key, press the [ENTER] key.

System initialization is performed immediately and the display returns to the Home screen previously shown before entering MENU mode.

Assigning the destinations of SUB IN and the

memory play signals

You can assign the destination channels of the signal received from the [SUB IN] jacks on the control panel as well as the memory play signal.

(1)Press the [ENTER] key to bring up the MENU screen.

When you bring up the MENU screen for the first time, "Mark point" is highlighted.

(2)Use the [MENU] dial to highlight "Input" and press the [ENTER] key.

The display now shows the screen on which you can assign the destination channels of "SubIn" and "MemPlay".

• To assign the destination channels of SUB IN

(3)While the "Assign/SubIn" item is highlighted, press the [ENTER] key.

The current setting ("15/16" by default) starts flashing.

(4)Use the [MENU] dial to select the destination channels and press the [ENTER] key.

You can select from channel pairs ("1/2", "3/4" and "5/6") as well as "-/-".

When "-/-" is selected, no channel is assigned.

79

Page 79
Image 79
Fostex LR16 manual To assign the destination channels of SUB, Use the Menu dial to highlight Input and press the Enter key