2

CPU364 Labels

Default Station Address Label

The Default Station Address label lists the MAC address to be used by this Interface.

Serial Number Label

The Serial Number Label indicates the serial number of this Interface.

Replaceable Surface Mount Fuse

A user-replaceable fuse is provided on the DC power that is supplied by the Ethernet Interface to the AAUI network port for use by an external transceiver. Replace only with a surface mount 2.69x2.69x6.1mm, 125V, 1A, fast-acting fuse (such as catalog number R454 001 made by LittelFuse; http://www.littelfuse.com). You may order this fuse from GE Fanuc. The part number is 44A725214-001.

Removing and Installing the Fuse

1. Be sure the Series 90-30 PLC baseplate power is OFF.

2. Remove the CPU364 module from the baseplate.

3. Remove the front shroud. The CPU364 is a two-board module, the fuse is located between the AAUI port and the 10Base-T port. See Figure 3-1.

4. Remove the blown fuse using a pair of small, bent-nose pliers.

5. Insert the new fuse. Make sure the fuse is seated properly.

6. Replace the front shroud and re-insert the CPU364 module.

7. Restore power to the baseplate.

2-20

TCP/IP Ethernet Communications for the Series 90™ PLC User's Manual– May 2002

GFK-1541B

Page 33
Image 33
GE GFK-1541B manual CPU364 Labels Default Station Address Label, Replaceable Surface Mount Fuse