HP 710F, 710E, 708D, 708E, 706C, 706D, 708C, 706A manual

Models: 708D 710E 706D 710F 706A 708C 706C 708E

1 123
Download 123 pages 44.25 Kb
Page 56
Image 56

￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿

￿￿￿￿￿￿￿￿￿

All configuration changes must be made through the master configuration port. This master configuration port has access to all options of the configuration mode. Please use the following procedure to configure your Print Master 700C model:

1.Connect a dumb terminal (or a PC running a terminal emulation program) to the master configuration port which is Port 6 on the 706C, Port 8 on the 708C, Port 10 on the 710C. From the factory, all serial ports are preset at 9600 baud rate, 8 word size, 1 stop bit, no parity and XON/XOFF disabled.

NOTE: If you wish to use the BayTech TERM.EXE program to configure your unit, refer to the instructions on the following page.

2.Make sure the keyboard of your computer is in the CAPS LOCK position.

All ports on Print Master must be off-line (i.e, all LEDs must be off except for the green power LED).

Send from the keyboard of the terminal or the PC Control-T(14 Hex) followed by capital C (43 Hex). These characters will not appear on the CRT screen.

If any red LEDs on Print Master illuminate when Control-Tand C are sent or if Print Master gives no response (no menus appear), this indicates that an incorrect character sequence has been received. If so, wait for Print Master to time out (LEDs will go out) and resend Control-Tand capital C.

The Model 700C will respond with the main configuration menu. From this point on, configuration of the 700C models will be menu driven.

48

Page 56
Image 56
HP 710F, 710E, 708D, 708E, 706C, 706D, 708C, 706A manual