RECOMMENDED CABLING USING HARDWARE OR XON/XOFF HANDSHAKING

MODEL 700 DCE

 

 

HP LASERJET

 

MALE DB-25

 

 

FEMALE DB-25

 

 

1

PGND

 

 

PGND

1

2

TXD

<

 

TXD

2

3

RXD

 

>

RXD

3

4

RTS

<

 

RTS

4

5

CTS

 

>

CTS

5

6

DSR

 

>

DSR

6

7

SGND

 

 

SGND

7

8

DCD

 

>

DCD

8

20

DTR

<

 

DTR

20

MINIMUM CABLING USING HARDWARE OR XON/XOFF HANDSHAKING

MODEL 700 DCE

 

HP LASERJET

MALE DB-25

 

FEMALE DB-25

2

TXD

2

3

RXD

3

 

 

4

 

 

5

 

 

6

7

SGND

7

20

DTR

20

NOTE: You may eliminate the Pin 20 to Pin 20 connection if you wish to use 3 wires and XON/XOFF handshaking only. You may use the pinouts above for any HP Draft Master plotter.