HP Enterprise File Services WAN Accelerator manual Out-of-Path, Static Cluster Deployment

Models: Enterprise File Services WAN Accelerator

1 124
Download 124 pages 48.85 Kb
Page 39
Image 39

Basic Steps (Server-Side)

‹Type the backup HP EFS WAN Accelerator IP address and port in the Backup Appliance IP and Port text boxes.

5.Save and apply the new configuration in the Management Console.

6.Begin optimization. View performance reports and system logs in the Management Console.

The server-side HP EFS WAN Accelerators are configured as out-of-path devices. For detailed information, see the HP StorageWorks Enterprise File Services WAN Accelerator Installation and Configuration Guide.

4 - OUT-OF-PATH NETWORK DEPLOYMENTS

Basic Steps (Client-Side)

Out-of-Path, Static Cluster Deployment

An out-of-path, static cluster deployment is appropriate when an in-path deployment is not an option. This deployment handles failures and scales to very high traffic levels.

The following figure illustrates a deployment where two HP EFS WAN Accelerators are configured as out-of-path devices on the server-side of the network and there are static clusters with in-path HP EFS WAN Accelerators on the client-side of the network.

Figure 4-4.Static Cluster Deployment

Perform the following steps for each HP EFS WAN Accelerator on the client-side of the network.

HP STORAGEWORKS ENTERPRISE FILE SERVICES WAN ACCELERATOR 2.1.5 DEPLOYMENT GUIDE