Basic Steps (Server-Side)

‹Type the IP address and port for the destination subnet, in the Destination Subnet and Port text boxes. To specify all ports, type all in the Port text box.

‹Under Targets, type the IP address and port number for the HP EFS WAN Accelerator that is the peer in the Target Appliance IP and Port text boxes. The IP address must be the Primary Port IP address on the target HP EFS WAN Accelerator. The default port is 7810.

‹If you have a backup, out-of-path HP EFS WAN Accelerator in your system (failover support), type the IP address and port for the backup appliance in the Backup Appliance IP and Port text boxes. Use the following format: 0.0.0.0/ 0. The default port is 7810.

5.Apply and save the new configuration in the Management Console.

6.Begin optimization. View performance reports and system logs in the Management Console.

The server-side HP EFS WAN Accelerator is configured as an out-of-path device. For detailed information, see the HP StorageWorks Enterprise File Services WAN Accelerator Installation and Configuration Guide.

1.Navigate to the Setup: Optimization Service - General Settings page in the Management Console.

2.Enable out-of path support click Enable Out-of-Path Support.

Figure 4-8.Setup: Optimization Service - General Settings Page

4 - OUT-OF-PATH NETWORK DEPLOYMENTS

HP STORAGEWORKS ENTERPRISE FILE SERVICES WAN ACCELERATOR 2.1.5 DEPLOYMENT GUIDE

37