HP Enterprise File Services WAN Accelerator manual Basic Steps Server-Side

Models: Enterprise File Services WAN Accelerator

1 124
Download 124 pages 48.85 Kb
Page 81
Image 81
Figure 7-7.Setup: Optimization Service - In-Path Rules Page

Basic Steps (Server-Side)

17.Repeat Step 4 for ports 139, 445, 21, and 80.

18.To pass through all other traffic, define a pass-through rule on the server-side HP EFS WAN Accelerator.

Figure 7-7.Setup: Optimization Service - In-Path Rules Page

19.Save and apply the new configuration in the Setup: Configuration Manager page.

20.Begin optimization. View performance reports and system logs in the Management Console.

The server-side HP EFS WAN Accelerator is configured as an out-of-path device. For detailed information, see the HP StorageWorks Enterprise File Services WAN Accelerator Installation and Configuration Guide.

IMPORTANT: This is an example of one type of WCCP deployment. You can also have deployments with both HP EFS WAN Accelerators configured as in-path devices and WCCP configured on one of them. In this case, you would configure the server-side as an in-path device and you would not define fixed-target rules on the client-side. For detailed information, contact HP technical support at http://www.hp.com.

7 - WCCP DEPLOYMENTS

HP STORAGEWORKS ENTERPRISE FILE SERVICES WAN ACCELERATOR 2.1.5 DEPLOYMENT GUIDE

75

Page 81
Image 81
HP Enterprise File Services WAN Accelerator Basic Steps Server-Side, 7. Setup Optimization Service - In-Path Rules Page