HP HyperFabric manual Running Diagnostics

Models: HyperFabric

1 156
Download 156 pages 43.28 Kb
Page 127
Image 127

Troubleshooting HyperFabric

Running Diagnostics

Running Diagnostics

Before running HyperFabric diagnostics:

1.Confirm HyperFabric adapters are installed on each node. Use the following command to display a list of HyperFabric adapters installed each node:

ioscan -funC clic

2.Check to see if HyperFabric software is installed. Use the following command to display the HyperFabric software version installed on each node:

swlist grep -i hyperfabric

3.Check the patch level. Use the following command to display the list of patches installed on each node:

swlist

Refer to the HyperFabric Release Note to determine which patches need to be installed.

4.Make sure the HyperFabric subsytem is started. Use the following command to determine if the HyperFabric subsystem is running on the node:

ps -ef grep clic

If the HyperFabric daemon (clic_mgmtd) is not running, start the HyperFabric subsystem by executing the following command:

/opt/clic/bin/clic_start

5.Make sure the correct IP addresses are assigned to the HyperFabric adapters. Use the following command to display all of the network interfaces and the IP addresses assigned to them:

netstat -in

If an IP address is not assigned to a HyperFabric adapter, execute the following commands in the order listed:

clic_shutdown

clic_init

clic_start

All of these commands reside in the /opt/clic/bin directory.

6.Check cabling to make sure all of the HyperFabric adapters are connected to the fabric.

7.Run the following command:

/opt/clic/bin/clic_stat -dALL

If a TCP/UDP/IP application is running:

Check the firmware file field to make sure the same version of firmware is downloaded on all of the HyperFabric adapters in the cluster. If this is not the case, run the following commands in the order listed below:

Chapter 5

103

Page 127
Image 127
HP HyperFabric manual Running Diagnostics