Syntax

prefix X:X::X:X/M [valid-lifetime (1-4294967295)] [preferred-lifetime (1-4294967295)]

Example

NGFW{running-l2tp0}prefix 100:0:0:0:0:0:0:0/64 valid-lifetime 2592000 preferred-lifetime 604800

NGFW{running-l2tp0}ra-autoconf-level

Modify IPv6 Router Advertisement autoconfiguration level.

Syntax ra-autoconf-level AUTOCONF

Possible values for AUTOCONF are:

none

No parameter is

autoconfigured

address

Address is

autoconfigured

other

Some

other

parameters are autoconfigured

full

Most

parameters

are autoconfigured

Example

NGFW{running-l2tp0}ra-autoconf-level full

NGFW{running-l2tp0}ra-interval

Modify IPv6 Router Advertisement interval value in milliseconds.

Syntax

ra-interval (90-1800000)

Example

NGFW{running-l2tp0}ra-interval 600

NGFW{running-l2tp0}ra-interval-transmit

Modify IPv6 Router Advertisement interval transmit.

Syntax

ra-interval-transmit (enabledisable)

Example

NGFW{running-l2tp0}ra-interval-transmit enable

NGFW{running-l2tp0}ra-lifetime

Modify IPv6 Router Advertisement prefix lifetime in seconds.

Syntax

ra-lifetime (0-9000000)

(0 if none)

Example

NGFW{running-l2tp0}ra-lifetime 1800

174 Edit Running Configuration Commands