For information about the attributes, consult the online help. However, some explanation is warranted here:

￿Current Speed, Max Slot Speed: As described in 1.8, “PCI subsystem” on page 23, the adapters installed in this slot and other slots in the same bus dictate the speed that the slot will run at. Consequently, the current speed of the slot may not be the maximum possible speed. The “X” in the Current Speed value indicates the slot is running in PCI-X mode (as opposed to running in PCI mode).

Some RXE-100 slots may indicate “NS” for the slot speed (see Figure 5-6 on page 136 for an example). NS stands for “not set”. These are even-numbered slots when the odd-numbered slot in the pair is running at 133 MHz. This is because if both slots in a pair are used, the maximum speed of both slots is 100 MHz.

￿PME Signal: PME (power management events) is a hardware signal that some PCI slots can supply. Most PCI cards do not implement PME and the x440 and RXE-100 slots do not support PME.

￿Bus Number: a system-assigned number for each bus. Useful for identifying slots that are on the same bus, but the bus number does not correlate to the slot numbers.

￿Low Profile: The slot only supports cards that have a half-height end plate. See the PCI Special Interest Group specifications of low-profile PCI adapters at http://www.pcisig.com/data/specifications/lowp_ecn.pdf.

￿LED Status: Table 5-1 shows the possible LED status messages and their meanings:

Table 5-1 LED status messages

Message

Meaning

Recommended Action

 

 

 

OK (no error)

None of the other conditions exist.

None

 

 

 

Hot eject successful

Adapter removal completed without

None

 

error.

 

 

 

 

Bus speed mismatch

A second adapter was hot-added

Either:

 

but its rated speed does not match

￿ Move one of the adapters to an empty

 

the current speed of the bus. The

bus, or a bus with an adapter of the

 

new adapter is held inoperative.

same speed.

 

 

￿ Reboot the server and the bus will

 

 

slow down so that both adapters can

 

 

operate.

 

 

 

Power fault on card in

Adapter has short-circuit or other

Remove the adapter and have it repaired

slot

problem preventing normal

or replaced.

 

operation.

 

 

 

 

134IBM ^xSeries 440 Planning and Installation Guide