IBM CF Series manual Saving Parameter Changes To Non-Volatile Memories

Models: CF Series

1 102
Download 102 pages 57.32 Kb
Page 86
Image 86

5.2 SAVING PARAMETER CHANGES TO NON-VOLATILE MEMORIES

All the programmable system parameters and calibration values are stored in non-volatile memories. They are stored on two different modules. The pixel gain correction values and camera exposure values are stored on the Video Motherboard and are accessed directly when scanning is active. All other parameters are stored on the Calibration and Line Splice ( CALS ) Board.

5.2.1 PIXEL CORRECTION AND EXPOSURE VALUES

Every time camera gain or exposure calibration is performed, new values will directly replace the old values in the memory and the old values are lost.

5.2.2SYSTEM PARAMETERS

Procedure for Issuing the SAVE Command:

In order to save parameter changes permanently in the non-volatile memory, issue either of the following SAVE commands:

From the Main Menu of the Local Control Terminal, press and hold down the <CTRL> key as you press <S> to save the changes made.

From the scanner’s keypad, press the <OPT> key and then press the down arrow key. On

the left side of the keypad display, “4. Save Parameters “ will appear. On the right side of the display , two messages will alternate : “ A : Proceed “ and “ OPT : Exit “. Press the keypad <A> key to save parameters followed by <OPT> to exit .

In either case, the system will beep to indicate that the command has been executed.

______________________________________________________________________

NOTE: Parameters may be saved only when the memory write protect switch on the CALS Board in set to “ Write Enable “. Since this is the default switch setting, it is not necessary to write-protect the non-volatile memory.

______________________________________________________________________

If the scanner returns the message, “SORRY, WRITE PROTECTED”, perform the following procedure to change the write protect status of the CALS Board first:

1. Open the front cover of the scanner and the card-cage door.

Page 86
Image 86
IBM CF Series manual Saving Parameter Changes To Non-Volatile Memories, Pixel Correction And Exposure Values