IBM CF Series manual 24 Set Autosize Parameters Menu

Models: CF Series

1 102
Download 102 pages 57.32 Kb
Page 58
Image 58
5.1.9AUTOSIZE PARAMETERS (9)

5.1.9AUTOSIZE PARAMETERS (9)

<This function is not implemented on any host scan softwares.>

When you press <9> to select auto size parameters, a menu similar to that shown in figure 5-24 will appear. This menu allows you to tune and test the scanner’s automatic sizing function.

----- AUTOSIZE PARAMETERS -----

0DIFFERENCE THRESHOLD : 09

1NUMBER IN ROW : 02

0

:

SET

PARAMETER 0

1 : SET PARAMETER 1

A

:

RUN

AUTOSIZE SEQUENCE

X : EXIT

CHOICE : X

Figure 5-24 Set Autosize Parameters Menu

Press <A> to run the auto sizing sequence. Feed in a document, then wait for the scanner to analyze it and display its width on the display terminal.

If the scanner is missing document edges and returning document width values that are two narrow, one or both of the autosizing parameters may need to be decreased slightly.

If the scanner is picking up false document edged and returning document width values that are too wide, one or both autosizing parameters may need to be increased slightly.

Press <0> to set a new value for parameter 0. Valid values for this parameter are two-digit hexadecimal numbers.

Press <1> to set a new value for parameter 1. Valid values for this parameter are also two-digit hexadecimal numbers.

Run an autosizing sequence immediately after you reset these parameters. Repeat the parameter setting and autosizing process until you are satisfied that the scanner autosizing function is returning accurate document width values.

Press <X> to exit the Autosize Parameters Menu and return to the Diagnostic Test Menu.

Page 58
Image 58
IBM CF Series manual 24 Set Autosize Parameters Menu