IBM CF Series Setup 2.2.1 Document Catch Installation, Environmental Concerns, Site, Airflow

Models: CF Series

1 102
Download 102 pages 57.32 Kb
Page 18
Image 18

2.2Setup

2.2.1Document Catch Installation

The document catch has three keyhole type slots. Insert the studs on the rear of the scanner (about an inch above the fan) into the three keyhole slots and push down firmly to seat them in the slots.

2.2.2 Environmental Concerns

The following conditions must be met to ensure acceptable working conditions for the scanner:

2.2.2.1 Site

The site has to be relatively dust free. The environment should also generate a low degree of static electricity.

2.2.2.2 Airflow

There must be at least one foot of clearance in the rear of the scanner to allow for proper airflow. Do not place the scanner near a heating panel or vent.

2.2.2.3 Ambient Light

In order to keep the light uniform on the document being scanned, no direct sunlight or bright lights should fall on the unit.

2.2.2.4 Vibration

Excessive vibrations in the room should be avoided in order for the delicate settings of the cameras to remain unchanged.

2.2.2.5 Temperature

The ambient temperature in the room should average between 18 and 30 degrees C (64-86 degrees F). The maximum ambient temperature for a non-working scanner must be between 5 and 40 degrees C (41-104 degrees F).

2.2.2.6 Humidity

The point of condensation should not be reached in the room.

2.3 CONNECTIONS

Page 18
Image 18
IBM CF Series Setup 2.2.1 Document Catch Installation, Environmental Concerns, Site, Airflow, Ambient Light, Vibration