5.1.1Set Global Parameters (1)
The Global Paramerters affect all scanner operations and will affect your entries in other menus.
When you press <1> for “Set Global Parameters,” a menu display similar to that in Figure
0 |
| MAXIMUM RESOLUTION | 1000 | |
1 |
| NUMBER OF CAMERAS | 8 | |
2 |
| SPLICE ON/OFF | On | |
3 |
| PIXEL SOURCE | Cameras | |
4 | NUMBER OF RESOLUTIONS | 8 | ||
5 |
| GRAY SCALE ON/OFF | Off | |
6 | NUMBER OF DOCUMENT SIZES | 5 | ||
7 |
| CCB WINDOW START | 0258 | |
8 |
| DISPLAY SYSTEM | In | |
9 |
|
| MIRROR | Off |
A |
| DEFAULT ZOOM STATE | Zoomed In | |
B |
| AUDIO LEVEL | F | |
S : SET | X : EXIT | CHOICE: X | ||
|
|
| Ready |
|
Figure 5-9 Global Parameters Menu
If you do not want to change anything, press <X> to exit and return to the Diagnostic Tests Menu.
If you press <S> for “Set,” the prompt, “Parameter Number,” will appear. Enter the number for the parameter you wish to change and a prompt will appear, allowing you to change its value.
<0> MAXIMUM RESOLUTION: In the example, the scanner has a maximum resolution of 500 dpi. (do not alter this parameter)
<1> NUMBER OF CAMERAS: In the example shown, four cameras are installed. (do not alter this parameter)
<2> SPLICE ON/OFF: This switch controls the electronic line splice adjustment function of the CALS Board. When the scanner is received from the factory, this function is