SCOM-100, User guide 22
s: Input signal name (Text: 0-15
characters, may include space
characters)
a: Transition selection (0: No alarm, 1:
positive 2: negative 3: both transitions)
d: Delay time in seconds (0-65535)
The following example illustrates how to configure digital
input 1 to initiate an alarm SMS after any signal
transition, a delay time of 30 seconds and a signal name
configured to “Door contact”.
The configuration command would be:
1100,0,1,Door contact,3,30
Send an SMS to the SCOM-100 unit with the respective
command.
Connect a contact or a loop wire to digital input 1
according to the wiring diagram in section 2.2. Close the
contact/loop and leave it closed for more than 30
seconds. The S/R SMS LED will blink and you will
receive an alarm SMS message and the following
contents:
My SCOM-100
Door contact
POSITIVE ALARM
Now open the input contact/loop for 30 seconds. You will
receive an alarm SMS message with the following
contents:
My SCOM-100
Door contact