SCOM-100, User guide

22

s:Input signal name (Text: 0-15 characters, may include space characters)

a:Transition selection (0: No alarm, 1: positive 2: negative 3: both transitions)

d:Delay time in seconds (0-65535)

The following example illustrates how to configure digital input 1 to initiate an alarm SMS after any signal transition, a delay time of 30 seconds and a signal name configured to “Door contact”.

The configuration command would be:

1100,0,1,Door contact,3,30

Send an SMS to the SCOM-100 unit with the respective command.

Connect a contact or a loop wire to digital input 1 according to the wiring diagram in section 2.2. Close the contact/loop and leave it closed for more than 30 seconds. The S/R SMS LED will blink and you will receive an alarm SMS message and the following contents:

My SCOM-100

Door contact

POSITIVE ALARM

Now open the input contact/loop for 30 seconds. You will receive an alarm SMS message with the following contents:

My SCOM-100

Door contact

Page 22
Image 22
Infinite Peripherals manual 1100,0,1,Door contact,3,30, My SCOM-100 Door contact