SCOM-100, User guide

30

The command to set an output after an initial delay is:

1020,m,n,h,mn

1020:

Command ID

m:

Module number (0 for SCOM-100 main

 

unit, 1-8 for DI-42 I/O expansion units)

n:

Output number (1-4 for SCOM-100

 

main unit, 1-2 for DI-42 I/O expansion

 

units)

h:

Delay on duration hours (0-21)

mn:

Delay on duration minutes (0-59)

4.4.6 Resetting a digital output after a delay

A command is available to reset a digital output with an initial delay time. The digital output’s switching behaviour is shown on the time-based diagram below.