SCOM-100, User guide

31

The command to reset an output after a delay is:

1021,m,n,h,mn

1021:

Command ID

m:

Module number (0 for SCOM-100 main

 

unit, 1-8 for DI-42 I/O expansion units)

n:

Output number (1-4 for SCOM-100

 

main unit, 1-2 for DI-42 I/O expansion

 

units)

h:

Delay off duration hours (0-21)

mn:

Delay off duration minutes (0-59)