| 42  | |
dt:  | ‘Derivative time’ (D) value between 1-  | |
  | 200 sec. A zero value disables the  | |
  | drivative part (not relevant for ON/OFF  | |
  | control)..  | 
  | 
ct:  | ‘Cycle time’ value between 1 and 15  | |
  | minutes, representing the pulse width  | |
  | modulation period of the digital output  | |
  | (not relevant for ON/OFF control).  | |
h:  | ‘Hysteresis’ value in [%] of the analog  | |
  | input scale   | |
  | (not relevant for PID control).  | |
Changing the set point value
1255,id,sp | 
  | 
1255:  | Command ID.  | 
id:  | Function block ID   | 
sp:  | Set point value in the range of the  | 
  | analog input scale.  | 
Setting the Function block state
The ON/OFF or PID control function block can be enabled or disabled with this SMS command:
1251,id,s | 
  | 
1251:  | Command ID.  | 
id:  | Function block ID   | 
s:  | 1: enable, 0:disable  | 
Controlling the Function block state
A digital input can be configured to control the Enabled/Disabled status of the function block.
The following command selects the digital input.