Firmware

4.2.4 Via the Serial Port

The following procedure is for using the HyperTerminal software application. In some cases, the HEX format file is available on the software CD and on the Web site.

Before you can load firmware through the serial port you need to convert the ROM code to HEX format. There is a DOS application, R2H.EXE that can be used to convert the ROM file to HEX format. The R2H.EXE application is available at ftp://ftp.lantronix.com/pub.

Put R2H.EXE and the *.ROM file into the same directory on a PC then open a DOS Window to that directory and type:

C:\ R2H filename

This will create a filename.hex file that you can load via the serial port.

Note: Do not switch off the power supply during the update. A loss of power while reprogramming will result in a corrupt program image and a nonfunctional unit.

To download firmware from a computer via the unit’s serial port:

1.Enter Monitor Mode via the serial port. (see Monitor Mode on page 7-1).

2.Download the firmware to the unit using the DL command.

3.Select Send Text File and select the *.HEX file to be downloaded. The downloaded file must be the .HEX (ASCII) version.

4.After the final record is received, the unit checks the integrity of the firmware image before programming the new firmware in the flash ROM. The following message displays when the firmware upgrade is complete.

*** NodeSet 2.0 ***

0>DL

02049 lines loaded.

Note: You can only update your unit 's internal Web interface using TFTP or Device Installer.

4-6

UDS-10 User Guide

Page 74
Image 74
Lantronix 10 manual Via the Serial Port