Configure

3.6.3 Flow

Flow control sets the local handshake method for stopping serial input/output.

Table 8 - Flow Control Options

Flow Control Option

Hex

No flow control

00

XON/XOFF flow control

01

Hardware handshake with RTS/CTS lines

02

XON/XOFF pass characters to host

05

3.6.4 Port Number

The setting represents the source port number in TCP connections, and is the number used to identify the channel for remote initiating connections. Default setting for Port 1 is 10001. Range: 0-65535 except for the following reserved port numbers:

Port Numbers

 

 

Reserved for

 

 

 

 

 

 

1 – 1024

 

 

Reserved (well known ports)

 

9999

 

Telnet setup

 

14000-14009

 

Reserved

 

30718

 

Reserved (77FEh)

 

10000-10999

 

 

Recommended ports, should be used for DeviceComm

 

 

 

Manager (COM1-COM256) or direct socket connections

 

 

 

 

 

The port number functions as the TCP/UDP source port number for outgoing packets. Packets sent to the unit with this port number are received to this channel. The port number selected is the Incoming TCP/UDP port and Outgoing TCP/UDP source port. Port 0 is used when you want the outgoing source port to change with each connection.

UDS-10 User Guide