3.6.10 Pack Control
Two
Pack control settings are enabled in Flush Mode. Set this value to 00 if specific functions are not needed.
Note: See Table 35 - Binary to Hexadecimal Conversion Table.
Table 14 - Pack Control Options
Option |
| 7 | 6 | 5 |
| 4 |
| 3 | 2 | 1 | 0 |
|
|
|
|
|
|
|
|
|
|
|
|
Idle Time |
|
|
|
|
|
|
|
|
|
|
|
Force transmit: 12ms |
|
|
|
|
|
|
|
|
| 0 | 0 |
Force transmit: 52ms |
|
|
|
|
|
|
|
|
| 0 | 1 |
Force transmit: 250ms |
|
|
|
|
|
|
|
|
| 1 | 0 |
Force transmit: 5sec |
|
|
|
|
|
|
|
|
| 1 | 1 |
Trailing Characters |
|
|
|
|
|
|
|
|
|
|
|
None |
|
|
|
|
|
|
| 0 | 0 |
|
|
One |
|
|
|
|
|
|
| 0 | 1 |
|
|
Two |
|
|
|
|
|
|
| 1 | 0 |
|
|
Send Characters |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
|
|
|
|
| |
Sequence |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| |
Send Immediately After |
|
|
| 1 |
|
|
|
|
|
|
|
Send chars |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
Idle Time: Idle time to "Force transmit" defines how long the unit should wait before sending accumulated characters. This wait period is between characters. If there is an idle period between characters equal to the force transmit set, then the unit will package up the serial data currently in the buffer and send it to the network.
Trailing Characters: In some applications, CRC, Checksum, or other trailing characters follow the