Firmware

4.In the Destination File field, enter the current internal operational code or WEB5 for the internal Web interface. (For UDS-10-IAP, AQ = Standard Tunnel, AM = Modbus, AD = DF1. For UDS-10, 3Q = Standard Tunnel)

5.In the Remote Host field, enter the IP address of the unit being upgraded.

6.Click the Put button to transfer the file to the unit.

Figure 18 - TFTP Dialog Box

The unit performs a power reset after the firmware has been loaded and stored.

4.2.3 Via Another Unit

To distribute firmware to another unit over the network:

1.Enter the host unit's Monitor Mode (see Monitor Mode on page 7-1).

2.Send the firmware to the receiving unit using the SF command, where x.x.x.x is the receiving unit's IP address.

SF x.x.x.x

The receiving unit performs a power reset after the firmware has been loaded and stored.

Note: You can only update your unit 's internal Web interface using TFTP or Device Installer.