Menu item

Supplies Info

Toner

Black Life

Magenta Life

Yellow Life

Cyan Life

Cartridge Type

Black

Init. 1000 Pages

Std. 2500 Pages

High 5000 Pages

Magenta

Init. 1000 Pages

Std. 1500 Pages

High 5000 Pages

Yellow

Init. 1000 Pages

Std. 1500 Pages

High 5000 Pages

Cyan

Init. 1000 Pages

Std. 1500 Pages

High 5000 Pages

Waste Toner Pack

Waste Pack Life

OPC Belt

OPC Belt Life

Replace OPC Belt

Not Replaced

Replaced

Fuser Unit

Fuser Unit Life

Replace Fuser

Not Replaced

Replaced

Scanner Carriage

Move to Lock

Not Execute

Execute

Description

Displays the remaining life information for supplies, and allows supply life to be reset when supplies are replaced

Notes:

The option to replace the photodeveloper belt and fuser appears only when the life information is low or empty.

The life information is displayed using a meter that shows one of five different levels (shown below). A full bar (five shaded boxes) indicates the supply item is new or full. An empty bar (five empty boxes) indicates the supply item is low or empty.

When you select Execute, the scanner is moved to the home position. Then, you can move the carriage switch (on the lower left corner of the scanner glass) to the Lock position for transportation.

Note: Not Execute is the factory default setting.

89

Page 89
Image 89
Lexmark X502N, X500n manual Supplies Info, Scanner Carriage