INSTALLATION | ||
|
|
For the 230/460/575V/ 60 HZ model which is not equipped with a plug, an input cord, or a receptacle, the input power supply leads are connected directly to the Reconnect Panel as shown Figure A.3. Refer to the specifications table at the beginning of this chapter for proper wiring sizes.
1.Connect the input power leads to terminals L1 and L2 on the Reconnect Panel Assembly.
a.For input power supply leads of 10 AWG or smaller, connect leads to Reconnect Panel using the ferrules
b.Strip fi" (13mm) of insulation from the input power supply leads.
c.Place ferrule over wire.
e.Torque the terminal screws to 16
FIGURE A.3 - Ground Connection For 230/460/575 Volt Models
CONNECT SHIELDING GAS
Customer must provide cylinder of appropriate type of shielding gas for gas metal arc welding for the process being used. See Figure A.4 for the location of the com- ponents used to connect the air supply cylinder.
WARNING
GAS UNDER PRESSURE IS EXPLO-
SIVE. ALWAYS KEEP GAS CYLIN-
DERS IN AN UPRIGHT POSITION AND
ALWAYS KEEP CHAINED TO UNDER-
CARRIAGE OR STATIONARY SUP-
PORT.
1.Set the gas cylinder on the rear platform of the SP 250.
2.Hook the chain in place to secure cylinder to rear of welder.
3.Remove the cylinder cap.
4.Inspect the cylinder valves for damaged threads, dirt, dust, oil or grease.
a. Remove dust and dirt with a clean cloth.
NOTE: DO NOT ATTACH THE REGULATOR IF OIL, GREASE OR DAMAGE IS PRESENT! Inform your gas supplier of this condition. Oil or grease in the pres- ence of high pressure oxygen is explosive.
5.Stand to one side away from the outlet and open the cylinder valve for an instant to blow away any dust or dirt which may have accumulated in the valve outlet.
BE SURE TO KEEP YOUR FACE AWAY FROM THE VALVE OUTLET WHEN OPENING THE VALVE.
6.Inspect the regulator for damaged threads, dirt, dust, oil or grease.
a. Remove dust and dirt with a clean cloth.
NOTE: DO NOT USE THE REGULATOR IF OIL, GREASE OR DAMAGE IS PRESENT! Have an authorized repair station clean the regulator or repair any damage.
7.Attach the flow regulator to the cylinder valve and tighten the union nut(s) securely with a wrench.
a.NOTE: If connecting the flow regulator to 100% CO2 cylinder, insert regulator adapter provided between regulator and cylinder valve. If adapter is equipped with a plastic washer, be sure it is seated properly to connect to the CO2 cylinder.
8.Connect one end of the inlet gas hose to the outlet fitting of the flow regulator.
9.Connect the other end of the inlet gas hose to the
10.Tighten both the union nuts securely with a wrench.
Return
Return