TROUBLESHOOTING & REPAIR

F-7

 

 

 

TROUBLESHOOTING GUIDE - Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

 

 

 

 

 

PROBLEMS

 

POSSIBLE AREAS OF

 

RECOMMENDED

 

 

(SYMPTOMS)

 

MISADJUSTMENTS(S)

 

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

 

 

FUNCTION PROBLEMS

 

 

 

 

 

 

 

 

 

The display backlight does not func-

1.

Check the input voltage at the

1.

With the display board discon-

tion.

 

 

machine. Input voltage must

 

nected test for 12VDC from pins

 

 

 

match the machine rating plate

 

1J1(+) to 2J1(-). If the 12VDC is

 

 

 

and the reconnect panel.

 

present and the display board

 

 

 

 

 

backlight does NOT function

 

 

 

 

 

then replace the display board.

 

 

 

 

 

See Wiring Diagram.

 

 

 

 

 

2.

If the 12VDC is not present at

 

 

 

 

 

pins 1J1 to 2J1 then perform the

 

 

 

 

 

Main Transformer Test.

 

 

 

 

 

3.

The control board may be faulty.

 

 

 

 

 

Replace.

 

 

 

 

 

 

The machine stops feeding wire

1.

Check for mechanical restric-

1.

Check the motor armature cur-

while welding and the MOTOR

 

tions in the wire feeding path.

 

rent. Normal armature current is

OVERLOAD message appears on

 

The gun cable may be clogged.

 

1.5 - 2.5 amps.

 

the display.

 

 

 

If the motor armature current is

 

 

 

 

 

normal the control board may be

 

 

 

 

 

faulty.-Replace.

 

 

 

 

 

2.

If the motor armature current is

 

 

 

 

 

high (over 3 amps) and there are

 

 

 

 

 

NO restrictions in the wire feed-

 

 

 

 

 

ing path then the motor or gear

 

 

 

 

 

box may be defective.-Replace.

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, con- tact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed call 216- 383-2531 or 1-800-833-9353