TROUBLESHOOTING & REPAIR

F-12

 

 

EXPLANATION OF PROMPTING AND ERROR MESSAGES (CONT’D)

Return to

Return to

ON SCREEN ERROR MESSAGE

DATA ***ERROR***

CHECK SETTINGS

PRESS PROCESS TO

CHECK SETTINGS

MESSAGE EXPLANATION

An attempt was made to recall a setup from memory that has improper set- tings due to excessive electrical interference. The SP-250 will recall the setup and reset the improper data to within machine limits. However, all settings should be checked, properly set if needed, and then resaved to that memory. This message alternates with the second message until the Process key is pressed.

Return to Master TOC

MOTOR OVERLOADED

Unit shut down even though trigger was closed. There is an excessive cur-

CHECK GUN, DRIVE

rent draw on the motor. Check for proper size tip, liner and drive rolls, for

 

any obstructions or bends in the gun cable, and any other factors that would

 

impede the wire feeding. To resume welding, simply pull the trigger.

 

 

XXXX ***ERROR***

Indicates that an error has occurred due to excessive electrical interference.

CHECK SETTINGS

All of these error types turn off the arc voltage, wire feed speed, and sole-

 

noid. Press the Process key, per second message, and check all settings

 

before continuing to weld.

PRESS PROCESS TO

XXXX

CHECK SETTINGS

IC3I

 

RTI

 

SWI

 

IOT

 

XIRQ

 

PWOF

 

DATA

This table shows all of the actual lettering which appears in place of XXXX. There is no reason to note which of these occurred unless it occurs fre- quently.

Return to Master TOC

GUN SWITCH BEING

Reminds the operator that the gun switch is being used to toggle between

USED FOR TOGGLE

memory 4 and memory 5 and, therefore, is not able to control IPM or arc

 

VOLTS.

 

 

CONNECT FOR

Reminds the operator to change the electrode polarity to negative when

NEG. POLARITY

Innershield wire type is selected.

 

 

Return to Master TOC

LOW LINE: CHECK RECONNECT PANEL

PRESS ANY KEY TO STOP MESSAGE

Indicates to operator that the input line voltage is too low to obtain the out- put set on the machine. The operator can continue to weld, but the voltage will be less than what is set on the machine. This message occurs when the line voltage is less than 75% of nominal line or if the voltage level set on the machine is not obtainable at that line voltage and load current. The opera- tor should check if the reconnect panel is wired properly. Lowering the set VOLTS and/or IPM can eliminate the message. Pressing any key or gun switch when the operator is not welding will stop the message from being displayed . Pressing any increment or decrement arrow keys or gun switch while welding will temporarily stop the message from being displayed (approximately 1.3 sec.) allowing the operator to view the increase or decrease in that setting.