Lincoln Electric SP-250 service manual Troubleshooting & Repair

Models: SP-250

1 113
Download 113 pages 49.69 Kb
Page 47
Image 47

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

TROUBLESHOOTING & REPAIR

TABLE OF CONTENTS

- TROUBLESHOOTING & REPAIR SECTION -

TROUBLESHOOTING & REPAIR SECTION

........... Section F

How to use Troubleshooting Guide

F-1

PC Board Troubleshooting Procedures

F-2

Troubleshooting Guide

F-3 - F10

Explanation of Prompting Error Messages

F11 -F-13

Test Procedures

 

SP-250 Main Transformer Test

F-14 - F-18

Static SCR Rectifier Test

F-19 - F-21

Active SCR Rectifier Test

F-22 - F-24

SP-250 Keypad Resistance Test

F-25 - F-27

Wire Drive Motor and Tach Feedback Test

.........F-28 - F-31

Oscilloscope Waveforms

F-32 - F-36

Replacement Procedures

 

Control Board Remove/Replace

F-37 - F-38

Keypad Remove/Replace

F-39 - F-40

Wire Drive Assembly Remove/Replace

F-41 - F-42

SCR Output Rectifier Remove/Replace

F-43 - F-44

Capacitor Bank Remove/Replace

F-45 - F-46

Main Transformer Remove/Replace

F-47 - F-48

Fan Motor Remove/Replace

F-49 - F-51

Retest After Repair

F-52

IDEALARC SP-250

Page 47
Image 47
Lincoln Electric SP-250 service manual Troubleshooting & Repair