F-9

TROUBLESHOOTING & REPAIR

 

 

 

 

F-9

 

 

 

 

 

 

 

TROUBLESHOOTING GUIDE - Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

 

 

 

 

PROBLEMS

 

POSSIBLE AREAS OF

 

RECOMMENDED

 

 

(SYMPTOMS)

 

MISADJUSTMENTS(S)

 

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WELDING PROBLEMS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The arc is unstable and or "hunting".

1.

Check for worn or melted con-

1.

Check for loose connections at

 

 

 

tact tip.

 

the output terminals, the choke,

 

 

 

 

 

the capacitor bank and all heavy

 

 

2.

Check for loose or faulty con-

 

current carrying leads.

 

 

 

 

nections on the work and elec-

 

 

 

 

 

 

 

 

 

 

trode cables.

2.

Make sure that the transformer

 

 

 

 

 

secondary

 

leads

are

securely

 

 

3.

Make sure electrode polarity is

 

connected to the SCR Rectifier

 

 

 

correct or welding process being

 

Assembly.

 

 

 

 

 

 

 

used.

 

 

 

 

 

 

 

 

 

 

 

3.

The output capacitor bank may

 

 

4.

Check for rusty or dirty wire.

 

be faulty.

Check for loose con-

 

 

 

 

 

nections at the capacitors. Also

 

 

5.

Make sure machine settings and

 

check

for

leaky

capacitors.

 

 

 

gas are correct for process

 

Replace if necessary.

 

 

 

 

being used.

 

WARNING:

The

liquid elec-

 

 

 

 

 

trolyte in these capacitors is

 

 

 

 

 

toxic. Avoid contact with any

 

 

 

 

 

portion of your body.

 

 

 

 

 

4.

The control board may be faulty.

 

 

 

 

 

Replace.

 

 

 

 

 

 

 

 

 

Weld bead is narrow or ropey. May

1.

Make sure the weld procedure

1.

The output capacitor bank may

have porosity with electrode stub-

 

and electrode polarity is correct

 

be faulty.

Check for loose con-

bing into plate.

 

for the process being used.

 

nections at the capacitors. Also

 

 

 

 

 

check

for

leaky

capacitors.

 

 

2.

Make sure shielding gas is cor-

 

Replace if necessary.

 

 

 

 

rect and flow is proper.

 

WARNING:

The

liquid elec-

 

 

 

 

 

trolyte in these capacitors is

 

 

3.

Make sure the weld joint is not

 

toxic. Avoid contact with any

 

 

 

"contaminated".

 

portion of your body.

 

 

 

 

 

2.

Perform

 

the SCR

Rectifier

 

 

 

 

 

Assembly Test.

 

 

 

 

 

 

3.

The control board may be faulty.

 

 

 

 

 

Replace.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, con- tact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed call 216- 383-2531 or 1-800-833-9353