Lincoln Electric SP-250 service manual #206 4J6 #208 16J6 #209 7J6 G1992 Code 9402 only

Models: SP-250

1 113
Download 113 pages 49.69 Kb
Page 64
Image 64

TOC

TOC

F-17

TROUBLESHOOTING & REPAIR

F-17

 

 

MAIN TRANSFORMER TEST

Return to Section

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master

Return to Master TOC

Return to Master TOC

Return to Master TOC

G1992 (Code 9402 only):

 

 

 

 

FROM

TO

EXPECTED

LEAD

LEAD

VOLTAGE

 

 

 

#202

#203

30 VAC

(6J3)

(7J3)

 

#202

#204 A

15 VAC

(6J3)

(5J3)

 

#203

#204 A

15 VAC

(7J3)

(5J3)

 

 

 

 

8.Turn OFF the machine

9.Locate the following leads on Plug J6 on the G2252 Control PC Board or Plug J3 on the G1992 Control PC Board. See Figures F.1A & F1.B.

G2252:

LEAD

PLUG

 

LOCATION

 

 

#206

4J6

#208

16J6

#209

7J6

 

 

G1992 (Code 9402 only):

LEAD

PLUG

 

LOCATION

 

 

#206

3J3

#208

1J3

#209

2J3

 

 

10.

Turn ON the machine.

11.Make the following voltage tests at Plug J6 on the G2252 Control PC Board, or at Plug J3 on the G1992 Control PC Board (Code 9402 only.)

a.Turn the machine OFF between each test.

b.Carefully insert the meter probes into the back of each Molex Plug pin cavity to perform the test.

G2252:

 

 

 

 

 

FROM

TO

EXPECTED

LEAD

LEAD

VOLTAGE

 

 

 

#208

#209

60 VAC

(16J6)

(7J6)

 

#208

#206

30 VAC

(16J6)

(4J6)

 

#209

#206

30 VAC

(7J6)

(4J6)

 

 

 

 

G1992 (Code 9402 only):

 

 

 

 

FROM

TO

EXPECTED

LEAD

LEAD

VOLTAGE

 

 

 

#208

#209

60 VAC

(1J3)

(2J3)

 

#208

#206

30 VAC

(1J3)

(3J3)

 

#209

#206

30 VAC

(2J3)

(3J3)

 

 

 

 

c.If any of the voltages tested are incorrect, check for loose or bro- ken leads between the test points and the main transformer.

d.If ALL the voltages tested are incorrect or missing, go to Step 12.

12.Test for correct nameplate input volt- age between the H1 lead at the ON/OFF POWER SWITCH to H2 or H3 at the reconnect panel. Voltage tested will vary depending on Input Voltage Connection. See wiring dia- gram for test point locations.

a.If the voltage test is incorrect,

-check for loose or broken leads between the reconnect panel and the ON/OFF POWER SWITCH.

-test the ON/OFF POWER SWITCH for proper operation.

IDEALARC SP-250

Page 64
Image 64
Lincoln Electric SP-250 service manual #206 4J6 #208 16J6 #209 7J6 G1992 Code 9402 only