OPERATION

B-4

 

 

Gun and Cable (K524-1) - A 12.5 ft. (3.8) GMAW gun and cable assembly, rated 200 amps 60% duty, is pro- vided with the SP-250 and includes a liner, diffuser, and contact tips for .035 (0.9mm) and .045 (1.2mm) electrodes. The gun is equipped with a Fast-Mate con- nector with additional control lead connections for the thumb activated 2 momentary position slide switch control designed into the gun handle for use with SP- 250 remote control features.

MACHINE CAPABILITY

The IDEALARC SP-250 is rated at the following duty cycles based upon 10 minute time period (i.e., for 60% duty cycle, it is 6 minutes on and 4 minutes off).

DUTY

AMPS

VOLTS

CYCLE

 

 

 

 

 

100%

145

26

60%

200

28

35%

250

26

 

 

 

LIMITATIONS

The SP-250 may not operate satisfactorily if powered with a portable or in-plant generating system.

IDEALARC SP-250

Page 20