Lincoln Electric SVM 113-A service manual Troubleshooting Guide, Output Problems

Models: SVM 113-A

1 106
Download 106 pages 31.95 Kb
Page 42
Image 42

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-4

 

 

 

 

F-4

TROUBLESHOOTING & REPAIR

Observe Safety Guidelines

 

 

 

TROUBLESHOOTING GUIDE

detailed in the beginning of this manual.

 

 

 

 

 

 

 

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

OUTPUT PROBLEMS

 

 

Major physical or electrical dam-

1. Contact your local Lincoln

1.

Contact The Lincoln Electric

age is evident.

 

Authorized Field

Service

 

Service Dept. (216) 383-2531 or

 

 

Facility.

 

 

1-800-833-9353 (WELD).

 

 

 

 

 

No weld output and no auxiliary

1.

Check brushes for wear. See

1.

Perform the Rotor Voltage

power. Engine operates normally.

 

the Maintenance

section of

 

Test.

 

 

this manual.

 

2.

If the rotor voltage is low or

 

 

 

 

 

2.

Check for loose or faulty con-

 

missing, check for the proper

 

 

nections at brush holders.

 

flashing current. Perform the

 

 

 

 

 

Rotor Flashing Circuit Test.

 

 

 

 

3.

Perform the Rotor Resistance

 

 

 

 

 

Test.

 

 

 

 

4.

The field capacitor (C1) or recti-

 

 

 

 

 

fier bridge (D1) may be faulty.

 

 

 

 

 

Test or replace.

 

 

 

 

5.

Test the rheostat (R1). Normal

 

 

 

 

 

resistance is 3.3 ohms.

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.

WELDANPOWER 125

Page 42
Image 42
Lincoln Electric SVM 113-A service manual Troubleshooting Guide, Output Problems