F-5

F-5

 

TROUBLESHOOTING & REPAIR

 

TROUBLESHOOTING GUIDE

Observe Safety Guidelines

 

 

detailed in the beginning of this manual.

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

 

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

OUTPUT PROBLEMS

 

 

 

 

 

No weld output, the auxiliary

1. Check the open circuit voltage

1.

Check the continuity (low resis-

power (230-115VAC) operates nor-

(OCV) at the welder output ter-

 

tance) from the positive output

mally. Engine runs normally.

minals. Normal is 75 to 82VDC

 

terminal,

through the

choke

 

with engine at high idle (3750

 

(L1), to the positive side of the

 

RPM) and the output rheostat at

 

output rectifier bridge (D2). See

 

maximum. If the correct OCV is

 

Wiring Diagram.

 

 

present, go to Step 3, below.

2.

Check the

continuity

(zero

 

 

 

2. If the open circuit voltage is

 

ohms) from the negative output

 

NOT present at the welder out-

 

terminal to the negative side of

 

put terminals, contact your

 

the output rectifier bridge (D2).

 

local Lincoln Electric Authorized

 

See Wiring Diagram.

 

 

Field Service Facility.

3. Perform

the Output Rectifier

 

 

 

3. Check the welding cables,

 

Bridge Test.

 

 

 

clamps and electrode holder for

4.

Perform

the

Main

Stator

 

loose or broken connections.

 

 

Winding Test.

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.

WELDANPOWER 125

Page 43
Image 43
Lincoln Electric SVM 113-A service manual Output Rectifier