Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-8

 

 

F-8

 

 

TROUBLESHOOTING & REPAIR

 

 

Observe Safety Guidelines

 

 

TROUBLESHOOTING GUIDE

 

detailed in the beginning of this manual.

 

 

 

 

 

 

 

 

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

 

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

ENGINE PROBLEMS

 

 

 

Engine will not start.

1.

Make sure the RUN/STOP

1. Check the fuel line for breaks or

 

 

 

Switch is in the “RUN” position.

obstructions.

 

 

2.

Make sure the fuel shut off valve

2. The spark plug may be faulty.

 

 

 

is in the open position.

Replace.

 

 

3.

Make sure the engine has ade-

3. Service the engine as outlined

 

 

 

quate fuel and oil.

in the Maintenance section of

 

 

4.

Adjust the choke to prevent car-

this manual.

 

 

 

 

 

 

 

buretor flooding.

4. The engine ignition module may

 

 

5.

Check the spark plug wire for

be faulty. Consult Briggs &

 

 

Stratton Service.

 

 

 

loose or faulty connections.

 

 

 

 

 

Engine runs erratic or stops run- 1.

The oil level may be low, acti-

1.

If the oil level is correct, the oil

ning.

vating the engine oil level shut-

 

level shutdown switch may be

 

down system. Check oil level.

 

faulty. Remove the lead running

2.

Check the spark plug wire for

 

from the oil level switch to the

 

ignition module.

If the engine

 

loose or faulty connection.

 

 

 

runs normally, the oil level

 

 

 

3.

The spark plug may be faulty.

 

switch is faulty.

Replace. DO

 

Replace.

 

NOT OPERATE

THE ENGINE

4.

The fuel and air mixture may be

 

WITHOUT OIL

LEVEL PRO-

 

TECTION.

 

 

out of adjustment. Consult the

 

 

 

 

 

 

 

Briggs & Stratton Owner’s

2.

The engine may require service

 

Manual.

 

to the head or carburetor.

5.

The fuel supply may be conta-

 

 

 

 

minated with water.

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.

WELDANPOWER 125

Page 46
Image 46
Lincoln Electric SVM 113-A service manual Engine Problems