OUTPUT RECTIFIER BRIDGE REMOVAL AND REPLACEMENT (continued)

11.With the 7/16" wrench, install the choke lead and the #203 lead to the positive heat sink.

12.With the 7/16" wrench, install the "N" negative lead and the #204 lead to the negative heat sink.

13.With the 7/16" wrench, install the heavy leads W1 and W2 to the stud terminals.

14.Replace the top cover of the control box and tighten the 8 sheet metal screws with the 5/16" nut driver.