to Section TOC

to Master TOC

F-37

F-37

TROUBLESHOOTING & REPAIR

BRUSH REMOVAL AND REPLACEMENT (continued)

PROCEDURE (continued)

Return

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return

Return to Master TOC

Return to Master TOC

Return to Master TOC

8.To reinstall the brush holder assembly, depress the spring-loaded brushes into the holder and slip a suitable non-metal- lic, fairly stiff retainer through the slots at the top and bottom of the holder. A cable tie works well; see Figure F.14. This will hold the brushes up so that you can eas- ily install the holder.

9.With the needle nose pliers, reinstall the red and the black wires to the appropriate terminals on the brushes. The red wire is inboard.

10.Slip the holder into position in the genera- tor end bracket. Be careful not to loosen the 2 attached wires.

11.Reinstall and tighten the 2 screws with the 1/4” nut driver.

12.Slowly remove the non-metallic retainer from the brush holder and let the brushes snap back against the slip rings.

13.Check the wire connections or clearance and tightness.

14.Snap the brush holder cover back into position.

WELDANPOWER 125

Page 75
Image 75
Lincoln Electric SVM 113-A service manual Procedure