TROUBLESHOOTING & REPAIR

 

TROUBLESHOOTING GUIDE

Observe Safety Guidelines

 

 

detailed in the beginning of this manual.

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

ENGINE PROBLEMS

 

Engine will NOT idle down to low

1. Make sure the idler control

1. With the idler control switch in

speed.

switch is in the “AUTO” idle

the “AUTO” position and all

 

position.

external loads removed, check

 

2. Remove any external load on

for 12VDC at leads #208 and

 

#209. See Wiring Diagram. If

 

the welder terminals or auxiliary

 

the 12VDC is present and the

 

power receptacles.

 

idler solenoid does not activate,

 

 

 

 

the solenoid may be faulty.

 

 

Replace.

 

 

2. If the 12VDC is NOT present at

 

 

leads #208 and #209, perform

 

 

the Main Stator Winding Test.

 

 

3. Check leads #15A (at stator) to

 

 

#16 (at idler P.C. board) for con-

 

 

tinuity (zero ohms). Check

 

 

leads #9A (at stator) to #9B (at

 

 

idler P.C. board) for continuity

 

 

(zero ohms). See Wiring

 

 

Diagram.

 

 

4. The idler P.C. board may be

 

 

faulty. Replace.

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.