F-12

F-12

TROUBLESHOOTING & REPAIR

TROUBLESHOOTING & REPAIR

TROUBLESHOOTING GUIDE

 

Observe Safety Guidelines

 

detailed in the beginning of this manual.

 

 

 

 

 

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

 

 

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

 

ENGINE PROBLEMS

 

 

 

 

The welding arc is “cold.” The

1. Check for loose or faulty con-

1. With the output control at max-

engine runs normally. The auxiliary

nections at the weld output ter-

imum, check for the correct

power functions normally.

minals and welding cable con-

open circuit voltage (OCV) at

 

nections.

the welder output terminals (75

 

2. The welding cable may be too

- 82 VDC). If the correct open

 

circuit voltage is present at the

 

long or coiled, causing an

 

output

terminals,

check

for

 

excessive voltage drop.

 

loose connections on the heavy

 

 

 

 

current carrying leads inside the

 

 

WELDANPOWER

125.

See

 

 

Wiring Diagram.

 

 

 

 

2. If the OCV is low at the welder

 

 

output

terminals,

perform

the

 

 

Engine

Throttle

Adjustment

 

 

Test.

 

 

 

 

 

3. Perform the Output Rectifier

 

 

Bridge Test.

 

 

 

 

4. Check for shorted or grounded

 

 

windings in the choke (L1).

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.

WELDANPOWER 125

Page 50
Image 50