F-59

F-59

TROUBLESHOOTING & REPAIR

RETEST AFTER REPAIR

Retest a machine:

If it is rejected under test for any reason that requires you to remove any mechanical part which could affect the machine’s electrical characteristics.

OR

• If you repair or replace any electrical components.

ENGINE OUTPUT

 

No Load RPM

Load RPM

Maximum Speed

3800

3500

Minimum Speed

3700

3300

WELDER/GENERATOR OUTPUT1

Output Control

Field Volts

Field Amps

Open Circuit

Load Volts

Load Amps

 

 

 

 

Volts

RMS

 

 

 

Maximum

40 - 47

4.0 - 6.4

75 - 82

22 - 28

125

- 135

 

Minimum

70 - 78

23 - 27

40

- 55

 

 

 

 

 

 

 

 

 

AUXILIARY POWER RECEPTACLE OUTPUT1

 

230 Volt Receptacle

 

115 Volt Receptacle2

Output

Open Circuit

Load Volts

Load Amps

Open Circuit

Load Volts

Load Amps

Control

Volts

 

 

Volts

 

 

Maximum

240 - 260

208 - 234

20.2 - 22.0

120 - 130

104 - 117

20.2 - 22.0

 

 

 

 

 

 

 

1Current Control Dial set at MAXIMUM.

2Output values of each receptacle can vary within the range shown but must be within 2 volts of each other.

WELDANPOWER 125

Page 97
Image 97
Lincoln Electric SVM 113-A service manual Retest After Repair, Engine Output, WELDER/GENERATOR OUTPUT1